Renogy 24/7 AI Agent | 6AM to 5PM PT Live Chat | Submit a Case Anytime Contact Us

400W 12V Starter Solar Panel Kit

SKU: RNG-KIT-RV400D-ADV30-US
$479.99
+   Renogy Rays after purchase.
Log In About Rays

  • N-type 25% cell efficiency
  • Solar Power Customized Kit
  • More energy, even in partially shaded areas
  • Reliable and Environmentally Friendly Power Supply
  • Multiple Options and Free Combination
  • Enhanced 25-year performance warranty

❓Need help before buying? Call Us: 1 (909) 287 7111

Solar Panel
Quantity:
Payment Methods
Delivery Methods
Delivery time: 1-3 business days.Shipping Policy
Lifetime Customer Support
30-Day Return and Refund Service
Show More Benefits Show Less
Frequently bought together
This Item
Save together with
Frequently Bought With
View more bundles Fold
Total Bundle Price
Add Bundle to Cart
Total Bundle Price
Description
Wiring Diagram
Includes
Specs
Downloads
FAQ
Reviews

400W 12V Starter Solar Panel Kit

An easy-to-install, cost-effective 400W solar kit built for off-grid RV living.

200W Solar Panel
Van Roof Fit

200W N-Type Solar Panel

Compact, lightweight 200W N-Type panel with up to 25% efficiency and lasting durability

Perfect Fit for Class B Van Roofs

A seamless, edge-to-edge fit with zero wasted space

100W Solar Panel
Space Saver

100W N-Type Solar Panel

Efficient, durable N-Type panels for compact, versatile vans

Perfect Fit for Mini Van Life

A seamless, edge-to-edge fit with zero wasted space

40A Charge Controller
Dual Protection

Rover Li 40A MPPT Solar Charge Controller

99% MPPT efficiency with smart charging and app control.

Comprehensive Internal and External Protection

A durable casing and rubber seal protect against rust, corrosion, and contamination, while built-in safety features ensure reliable, long-lasting performance.

How They Work
2*200W
4*100W

2*200W 12V Rigid Solar Panel Kit

  • 200W N-Type 16BB Solar Panel x2

  • Rover Li 40A MPPT Charge Controller x1

  • 1FT 8AWG Fuse Cable x1

  • 20A Waterproof in-Line Fuse Holder w/Fuse x2

  • 20FT 10AWG Solar Adaptor Cable x1

  • 60A ANL Fuse Set w/ Fuse x1

  • 8FT 8AWG Wire Copper Tray Cable x1

  • Solar Y Branch Connectors MMF+FFM Pair x1

  • Solar Panel Mounting Z Bracket Mount x4

  • BT-2 Bluetooth Module x1

2*200W 12V Flexible Solar Panel Kit

  • 200W Flexible Solar Panel x2

  • Rover Li 40A MPPT Charge Controller x1

  • 1FT 8AWG Fuse Cable x1

  • 20A Waterproof in-Line Fuse Holder w/Fuse x2

  • 20FT 10AWG Solar Adaptor Cable x1

  • 60A ANL Fuse Set w/ Fuse x1

  • 8FT 8AWG Wire Copper Tray Cable x1

  • Solar Y Branch Connectors MMF+FFM Pair x1

  • Solar Panel Mounting Z Bracket Mount x4

  • BT-2 Bluetooth Module x1

4*100W Solar Panel Kit

  • 100W N-Type Solar Panel x4

  • 30A Adventurer PWM Charge Controller x1

  • Cable Entry Housing x1

  • 30FT 10AWG Solar Adaptor Kit x1

  • 16FT 10AWG Tray Cables x1

  • Solar Y Branch Connectors x3

  • Mounting Z Brackets x4

  • BT-1 Bluetooth Module x1

Specifications

200W-Specifications

Max Power at STC
200W
Open Circuit Voltage
37.44V
Short Circuit Current
6.85A
Optimum Operating Voltage
31.03V
Optimum Operating Current
6.45A
Maximum System Voltage
600VDC
Maximum Series Fuse Rating
15A
Module Efficiency
20.7%
Operating Temperature:
-40°F~185°F / -40℃~85℃
Dimensions:
1262x764x30mm/49.7x30.1x1.2in
Weight:
10.6kg/23.4lbs

Renogy 16BB N-Type 100 Watt Solar Panel

Max Power at STC
100W
Open Circuit Voltage (VOC)
22.79V
Short Circuit Current (ISC)
5.31A
Optimum Operating Current (IMP)
5.01A
Optimum Operating Voltage (VMP)
19.97V
Operating Temperature
-40°F to 185°F(-40℃ to +85℃)
Dimensions
34.1*22.8*1.2in/865x578x30mm
Weight
13.0 lb (5.9 kg)

200W Flexible Solar Panel

Maximum Power at STC
200W
Module Efficiency
16.7%
Optimum Operating Voltage (Vmp)
20.1V
Open-Circuit Voltage (Voc)
23.9V
Optimum Operating Current (Imp)
10.02A
Short Circuit Current
10.74A
Operating Temperature
-40°F to 176°F (-40ºC to +80ºC)
Maximum Series Fuse Rating
15A
Weight
4.9 kg / 10.8 lbs
Dimensions
1605 x 748 x 3 mm (63.2 x 29.4 x 0.1 in)

ROVER LI 40A MPPT CHARGE CONTROLLER

Nominal System Voltage
12V/24V Auto Recognition
Max. PV Input Voltage
100 VDC
Max Battery Voltage
32V
Rated Charge Current
40A
Max. PV Input Power
12V/520W, 24V/1040W

30A Adventurer Li PWM Charge Controller w/ LCD Display

Nominal Voltage
12 VDC/ 24 VDC
USB Output
5V, 2.4A Max
Rated Charge Current
30A
Max. PV Input Voltage
50 VDC
Equalization Voltage
Sealed: 14.6 V; Gel: None; Flooded: 14.8 V
Boost Voltage
Sealed: 14.4 V; Gel: 14.2 V; Flooded: 14.6 V; Lithium: 14.2 V
Float Voltage
13.8 V
Max. PV Input Power
12V(400W) / 24V(800W)
Dimensions
6.56 x 4.50 x 1.90 inches
Weight
0.6 lbs

Frequently Asked Questions

1. What do I need to complete my off-grid solar power system ?

A solar panel has to be connected to a charge controller to regulate current, and a battery to store the electrical power. You will need adapter kit cables to wire the solar panel(s) and charge controller, and tray cables connecting the charge controller to a deep-cycle battery.

2. What does off-grid and on-grid mean ?

On-grid simply means solar power equipment (array or solar panel) is connected to the electrical grid, while off-grid refers to systems that are not connected to the grid and therefore store the generated power for later use. Off-grid systems are not affected by grid blackouts.

3. Why is my solar panel under producing ?

Solar panel performance may be hindered for a number of reasons. Most commonly environmental conditions such as indirect sunlight, temperature rise, cloudy sky, and dirt and stain build up on the top glass will cause a reduced power output.

4. How should I connect solar panels in my electrical circuit (series vs parallel)?

Solar panels can be connected in series or in parallel to meet your electrical circuit size and power demand. Connecting solar panels in series will have the effect of adding up their operating voltage output, while system current output will be the same as that for one panel. While, connecting solar panels in parallel will have a different effect; individual panels operating current output will add up to be the system output current, while system output voltage will be the same as the output voltage of one solar panel. To meet the optimum power output and system rating for your power system, you can use both parallel and series connections.

5. How many solar panels do I need ?

The best way to gauge how many solar panels you need, is to understand and define the power load needed from this system. Power is measured in Watts, and capacity is commonly measured in Watt-hours (multiplying power output in watts by the required number of hours of operation multiplied by a safety factor of 1.5-2). Therefore, it is wise to size your battery bank first based on the minimum required capacity, and accordingly decide how many panels or how much power input is needed.

6. How should I wire my panels with an MPPT charge controller?

The panels can be wired in series, parallel, or a combination of both series and parallel configurations.

7. What are the advantages of Renogy MPPT technology?

Renogy Rover Series solar charge controllers use Power Catcher MPPT algorithm to always ensure the charge controller converts most energy by locking to the most optimal maximum power point.

8. Will this solar kit power my AC unit ?

To determine what size solar kit is appropriate, you must first define the total load to be expected of the solar power system. Most manufacturers will publish a specification sheet of the AC unit online and will include a nameplate sticker on the AC unit's body. Both can be used to determine the actual power rating of the AC. BTU is a common measuring unit for energy in AC and water heater products, however we are interested in the energy rate, or simply power. Power will be listed in units of Watts and can be used to determine the total load resulting from running the intended AC unit. Multiply the power rating recorded in watts by the total number of hours of operation intended, to obtain the total watt-hours. Divide the total watt-hours by the peak sun hours in the location of installation, and multiply by a safety factor of 1.5-2, to obtain the total number of watts your panels should produce to power the air conditioner load. The total power load can be divided by the power output of one panel to obtain the number of panels needed.